• page_head_bg

1P 2P 3P 4P DC SPD Lighting Arrester Surge Protector Device 18 Shield Structure solar PV photovoltaic system

1P 2P 3P 4P DC SPD Lighting Arrester Surge Protector Device 18 Shield Structure solar PV photovoltaic system

Short Description:

The lightning protection block with the maximum discharge current of 80KA is suitable for the lightning protection of the main power supply in important places. This product is widely used in power systems such as mobile communication base stations, microwave communication bureaus/stations, telecommunications equipment rooms, industrial factories and mines, civil aviation, finance, securities, etc., such as various power distribution stations, power distribution rooms, power distribution cabinets, AC and DC power distribution Screens, switch boxes, and other important equipment that is vulnerable to lightning strikes.


Product Detail

Product Size

Installation Instructions

Product Tags

Surge protector (SPD) is an indispensable device in lightning protection of electronic equipment. Its working principle is that under normal circumstances, SPD is in a very high resistance state, thus ensuring the normal operation of power supply system. When the power supply system gradually increases with the surge current and voltage, the resistance of SPD continues to decrease, and SPD is immediately turned on in nanosecond time, and the surge energy is discharged into the ground through SPD; After the surge, the surge protector quickly reverts to the high impedance state, thus not affecting the normal power supply of the system.

With 35mm standard DIN-rail mounting, connecting copper stranded conductor is 2.5~35 mm².

At front of LHSPD  each pole must be setted protection ---used fuse or miniature circuit breaker lightning  current  LHSPD protection ,after LHSPD breakdown to short circuit protection.

LHSPD  install on protected line (equipment)  to  the front  and c onnected to  supply line.

A class  products  install in the building home-entry line hold large surge current total distribution box.

B\C class products most install on the floor  distribution box.

D class products close to the front – end  equipment  that smaller surge current, smaller residual voltage

_0011__REN6239
_0000__REN6250
_0003__REN6247

Accessories Diagram

Surge Protector Device 27OBO Structure 01
Surge Protector Device 27OBO Structure 02
Payment methodsPayment before Delivery Supply capacity: 500pc/day
Delivery time ship the goods in 10days after advanced payment Post-sales service: Express to the designated place
Time for logistics: due to the distence Specification standard: LH-40
Samples: we  charge you for samples
_0019__REN6260

LH-40/2P
Maximum continuous operating voltage Uc 385V~
Nominal discharge current In 20KA
Maximum discharge current Imax 40KA
Voltage protection level Up ≤ 1.8KV
Appearance: full arc, red, pad printing

_0005__REN6245

LH-40/4P
Maximum continuous operating voltage Uc 385V~
Nominal discharge current In 20KA
Maximum discharge current Imax 40KA
Voltage protection level Up ≤ 1.8KV
Appearance: flat, white, pad printing

LH-40/3+NPE NPE
Maximum continuous operating voltage Uc 385V 255V~
Nominal discharge current In 20KA 20KA
Maximum discharge current Imax 40KA 40KA
Voltage protection level Up ≤ 1.8KV ≤ 1.3KV
Appearance: full arc, white, pad printing

Model Definition

Model:LH-40/385-4 LH Lightning pick surge protector
40 Maximum discharge current: 40, 60
385 Maximum continuous operating voltage: 385, 440V~
4 Mode: 1p, 2p, 1+NPE, 3p, 4p, 3+NPE

Technical Parameters

Model LH-10 LH-20 LH-40 LH-60 LH-80 NPE
Maximum continuous operating voltage Uc 275/320/385/440V~ (optional can be customized)
Nominal discharge current In (8/20) 5 10 20 30 40  
Maximum discharge current Imax (8/20) 10 20 40 60 80  
Protection level Up ≤1.0/1.2/1.4KV ≤1.2/1.4/1.5KV ≤1.5/1.6/1.8/2.0KV ≤1.6/1.8/2.1/2.2KV ≤1.6/1.8/2.1/2.3KV ≤1.3/1.4/1.6/1.8KV
Optional appearance Plane, full arc, arc, with white bars, no white bars 18 wide, 27 wide, 36 wide (optional, can be customized)
Can add remote signal and discharge tube  
working environment -40 ℃~+85℃
Relative humidity ≤95%(25℃)
colour White, red, orange (optional, can be customized)
Remark Power surge protector, suitable for three-phase five-wire power supply system, guide rail installation.

Uses and characteristics of performance

1. LPZOA area All objects in the exposed area, outside the building and this area may be struck by lightning directly and lead away all lightning current, and the lightning electromagnetic field in this area is not attenuated.

2. LPZOB Area Every object in this area cannot be struck by lightning directly, but the magnitude of lightning electromagnetic field in this area is the same as that in LPZOA area.

3. LPZ1 Area Every object in this area cannot be struck by lightning directly, and the current flowing through each conductor is smaller than that in LPZOB area, so the lightning electromagnetic field in this area may be attenuated, depending on shielding measures.

4. Subsequent lightning protection areas (LPZ2, etc.) When the lightning current and electromagnetic field need to be further reduced, the subsequent lightning protection zone should be introduced, and the required conditions of the subsequent lightning protection zone should be selected according to the environment required by the system to be protected. All power lines and signal lines enter the protected space LPZ1 from the same place, and are equipotentially connected on the equipotential bonding belt 1 located in LPZOA and LPZ1 (generally grounded in the incoming room). These lines are equipotentially connected on the equipotential bonding belt 2 at the interface between LPZ1 and LPZ2. Connect the shield 1 outside the building to the equipotential bonding belt 1 and the inner shield 2 to the equipotential bonding belt 2. The LPZ2 constructed in this way makes it impossible for lightning current to be introduced into this space and pass through this space.

Used place: It can be used in power distribution cabinetdistribution box and.

Material and production process: Plastic shell, chip, copper, and other accessories。Plastic shell, chip, copper, and other accessories.Spot welding, glue filling, soldering, printing and module mounting.

Compared with our peers, the characteristics of our products are:Product inspection meets the national standard。


  • Previous:
  • Next:

  •  Surge Protector Device 27OBO Structure 03

    Shell material: PA66/PBT

    Feature: pluggable module

    Remote control monitoring function: with configuration

    Shell color: default, customizable

    Flame retardant rating: UL94 V0

    _REN6770 LH-40 Surge Protector Device 18 Shield Structure
    Model Combination Size
    LH-40/385/1P 1p 18x90x66(mm)
    LH-40/385/2P 2p 36x90x66(mm)
    LH-40/385/3P 3p 54x90x66(mm)
    LH-40/385/4P 4p 72x90x66(mm)

    ●The power must be cut off before installation, and live operation is strictly prohibited

    ●It is recommended to connect a fuse or automatic circuit breaker in series at the front of the lightning protection module

    ●When installing, please connect according to the installation diagram. Among them, L1, L2, L3 are phase wires, N is the neutral wire, and PE is the ground wire. Do not connect it wrongly. After installation, close the automatic circuit breaker (fuse) switch

    ●After installation, (18mm lightning protection module must be inserted in place) check whether the lightning protection module is working properly 10350gs, discharge tube type, with window: During use, the fault display window should be checked and checked regularly. When the fault display window is red (or the remote signal terminal of the product with remote signal output alarm signal), it means the lightning protection module In the event of failure, it should be repaired or replaced in time.

    ●Parallel power supply lightning protection modules should be installed in parallel (Kevin wiring can also be used), the width of the single chip is 36mm, and it can be connected by double wiring. Generally, you only need to connect any one of the two wiring posts. . The connecting wire must be firm, reliable, short, thick, and straight.

    Installation diagram

    https://www.zjleihao.com/uploads/Surge-Protector-Device-18-Shield-Structure-04.jpg