• page_head_bg

Hot Selling for Structure Duowei Steel Structure Building Materials For Warehouse Workshop

Hot Selling for Structure Duowei Steel Structure Building Materials For Warehouse Workshop

Short Description:

The lightning protection block with the maximum discharge current of 120KA is suitable for the lightning protection of the main power supply in important places. This product is widely used in power systems such as mobile communication base stations, microwave communication bureaus/stations, telecommunications equipment rooms, industrial factories and mines, civil aviation, finance, securities, etc., such as various power distribution stations, power distribution rooms, power distribution cabinets, AC and DC power distribution Screens, switch boxes, and other important equipment that is vulnerable to lightning strikes.


Product Detail

Product Size

Installation Instructions

Product Tags

Our aim is usually to give superior quality items at aggressive rates, and top-notch company to clients around the earth. We have been ISO9001, CE, and GS certified and strictly adhere to their good quality specifications for Hot Selling for Structure Duowei Steel Structure Building Materials For Warehouse Workshop, Since the manufacturing unit founded, we have now committed into the progress of new goods. Along with the social and economic pace, we’ll continue to carry forward the spirit of “high excellent, efficiency, innovation, integrity”, and stay with the operating principle of “credit initially, customer 1st, good quality excellent”. We’ll produce a excellent foreseeable future in hair output with our companions.
Our aim is usually to give superior quality items at aggressive rates, and top-notch company to clients around the earth. We have been ISO9001, CE, and GS certified and strictly adhere to their good quality specifications for , Our stock have valued 8 million dollar , you can find the competitive parts within short delivery time. Our company is not only your partner in business, but also our company is your assistant in the coming corporation.
TN-S system: The N-line and PE-line of this system are only connected to the outgoing terminal at the bottom side of the transformer and connected to the ground wire. Before entering the general distribution box of the building, the N-line and PE-line are wired independently, and surge protectors are installed between the phase line and PE-line.

(1) direct lightning means that lightning strikes directly on the structure of buildings, animals and plants, causing damage to buildings and casualties due to electrical effects, thermal effects and mechanical effects.

(2) Inductive lightning means that when lightning discharges to the ground between Lei Yun or Lei Yun, electromagnetic induction is generated in the nearby outdoor transmission signal lines, buried power lines and connecting lines between equipment, and the electronic equipment connected in series in the middle of the lines or terminals is damaged. Although induction lightning is not as violent as direct lightning, its occurrence probability is much higher than direct lightning.

(3) Lightning surge is a form of lightning hazard that people pay great attention to due to the continuous use of microelectronics in recent years, and its protection methods are constantly improving. The most common electronic equipment hazards are not caused by direct lightning strikes, but by current surges induced in power supply and communication lines when lightning strikes. On the one hand, due to the highly integrated internal structure of electronic equipment, the voltage and overcurrent resistance of the equipment are reduced, and the bearing capacity of lightning (including induced lightning and operating overvoltage surge) is reduced; on the other hand, due to the increase of signal source paths, the system is more vulnerable to lightning wave intrusion than before. Surge voltage can run into computer equipment through power lines or signal lines. The main sources of surge voltage in signal system are induced lightning strike, electromagnetic interference, radio interference and electrostatic interference. Metal objects (such as telephone lines) are affected by these interference signals, which will cause errors in data transmission and affect transmission accuracy and transmission rate. Eliminating these interferences will improve the transmission condition of the network. GE company in the United States measured that the surge voltage of low-voltage distribution lines (110V) in general households, restaurants, apartments, etc., which exceeded the original working voltage by more than one time, reached more than 800 times in 10000h (about one year and two months), among which more than 300 times exceeded 1000V. Such surge voltage is entirely possible to damage electronic equipment at one time.

Accessories Diagram

Surge Protector Device 27OBO Structure 001

Testing Report

Surge Protector Device 27OBO Structure 002
_0013__REN6237

LH-80/4P
Maximum continuous operating voltage Uc 385V~
Nominal discharge current In 40KA
Maximum discharge current Imax 80KA
Voltage protection level Up ≤ 2.2KV
Appearance: curved, white, laser marking

_0019__REN6230

LH-120/4P
Maximum continuous operating voltage Uc 385V~
Nominal discharge current In 60KA
Maximum discharge current Imax 120KA
Voltage protection level Up ≤ 2.7KV
Appearance: flat, red, pad printing

Model meaning

MODEL:LH-80/385-4

LH Lightning pick surge protector
80 Maximum discharge current: 80, 100, 120
385 Maximum continuous operating voltage: 385, 440V~ T2: on behalf of Class II test products
4 Mode: 1p, 2p, 1+NPE, 3p, 4p, 3+NPE

Technical Parameters

Model LH-80 LH-100 LH-120 LH-150 LH-200
Maximum continuous operating voltage Uc 275/320/385/440V~ (optional can be customized)
Nominal discharge current In (8/20) 40 60 60 80 100
Maximum discharge current Imax (8/20) 80 100 120 150 200
Protection level Up ≤1.8/2.0/2.3/2.4KV ≤2.0/2.2/2.4/2.5KV ≤2.3/2.5/2.6/2.7KV ≤2.5/2.7/2.9/3.0KV ≤2.7/3.0/3.2/3.5KV
Optional appearance Plane, full arc, arc (optional, customizable)
Can add remote signal and discharge tube Can add remote signal and discharge tube
working environment -40 ℃~+85℃
Relative humidity ≤95%(25℃)
colour White, red, orange (optional, can be customized)
Remark Power surge protector, suitable for three-phase five-wire power supply system, guide rail installation.

Our aim is usually to give superior quality items at aggressive rates, and top-notch company to clients around the earth. We have been ISO9001, CE, and GS certified and strictly adhere to their good quality specifications for Hot Selling for Structure Duowei Steel Structure Building Materials For Warehouse Workshop, Since the manufacturing unit founded, we have now committed into the progress of new goods. Along with the social and economic pace, we’ll continue to carry forward the spirit of “high excellent, efficiency, innovation, integrity”, and stay with the operating principle of “credit initially, customer 1st, good quality excellent”. We’ll produce a excellent foreseeable future in hair output with our companions.
Hot Selling for , Our stock have valued 8 million dollar , you can find the competitive parts within short delivery time. Our company is not only your partner in business, but also our company is your assistant in the coming corporation.


  • Previous:
  • Next:

  •  Surge Protector Device 27OBO Structure 003

    Shell material: PA66/PBT

    Feature: pluggable module

    Remote control monitoring function: none

    Shell color: default, customizable

    Flame retardant rating: UL94 V0

    https://www.zjleihao.com/uploads/27OBO-Structure-4.jpg.jpg
    Model   Combination Size
    LH-120/385/1P 1p 27x90x60(mm)
    LH-120/385/2P 2p 54x90x60(mm)
    LH-120/385/3P 3p 81x90x60(mm)
    LH-120/385/4P 4p 108x90x60(mm)

    ●The power must be cut off before installation, and live operation is strictly prohibited
    ●It is recommended to connect a fuse or automatic circuit breaker in series at the front of the lightning protection module
    ●When installing, please connect according to the installation diagram. Among them, L1, L2, L3 are phase wires, N is the neutral wire, and PE is the ground wire. Do not connect it wrongly. After installation, close the automatic circuit breaker (fuse) switch
    ●After installation, check whether the lightning protection module is working properly
    10350gs, discharge tube type, with window: During use, the fault display window should be checked and checked regularly. When the fault display window is red (or the remote signal terminal of the product with remote signal output alarm signal), it means the lightning protection module In the event of failure, it should be repaired or replaced in time.
    ● Parallel power supply lightning protection modules should be installed in parallel (Kevin wiring can also be used), or double wiring can be used to connect. Generally, you only need to connect any one of the two wiring posts. The connecting wire must be firm, reliable, short, thick, and straight.

    Surge Protector Device 27OBO Structure 04