TN-S system: The N-line and PE-line of this system are only connected to the outgoing terminal at the bottom side of the transformer and connected to the ground wire. Before entering the general distribution box of the building, the N-line and PE-line are wired independently, and surge protectors are installed between the phase line and PE-line.
(1) direct lightning means that lightning strikes directly on the structure of buildings, animals and plants, causing damage to buildings and casualties due to electrical effects, thermal effects and mechanical effects.
(2) Inductive lightning means that when lightning discharges to the ground between Lei Yun or Lei Yun, electromagnetic induction is generated in the nearby outdoor transmission signal lines, buried power lines and connecting lines between equipment, and the electronic equipment connected in series in the middle of the lines or terminals is damaged. Although induction lightning is not as violent as direct lightning, its occurrence probability is much higher than direct lightning.
(3) Lightning surge is a form of lightning hazard that people pay great attention to due to the continuous use of microelectronics in recent years, and its protection methods are constantly improving. The most common electronic equipment hazards are not caused by direct lightning strikes, but by current surges induced in power supply and communication lines when lightning strikes. On the one hand, due to the highly integrated internal structure of electronic equipment, the voltage and overcurrent resistance of the equipment are reduced, and the bearing capacity of lightning (including induced lightning and operating overvoltage surge) is reduced; on the other hand, due to the increase of signal source paths, the system is more vulnerable to lightning wave intrusion than before. Surge voltage can run into computer equipment through power lines or signal lines. The main sources of surge voltage in signal system are induced lightning strike, electromagnetic interference, radio interference and electrostatic interference. Metal objects (such as telephone lines) are affected by these interference signals, which will cause errors in data transmission and affect transmission accuracy and transmission rate. Eliminating these interferences will improve the transmission condition of the network. GE company in the United States measured that the surge voltage of low-voltage distribution lines (110V) in general households, restaurants, apartments, etc., which exceeded the original working voltage by more than one time, reached more than 800 times in 10000h (about one year and two months), among which more than 300 times exceeded 1000V. Such surge voltage is entirely possible to damage electronic equipment at one time.
LH-80/4P
Maximum continuous operating voltage Uc 385V~
Nominal discharge current In 40KA
Maximum discharge current Imax 80KA
Voltage protection level Up ≤ 2.2KV
Appearance: curved, white, laser marking
LH-120/4P
Maximum continuous operating voltage Uc 385V~
Nominal discharge current In 60KA
Maximum discharge current Imax 120KA
Voltage protection level Up ≤ 2.7KV
Appearance: flat, red, pad printing
MODEL:LH-80/385-4 |
LH | Lightning pick surge protector |
80 | Maximum discharge current: 80, 100, 120 | |
385 | Maximum continuous operating voltage: 385, 440V~ T2: on behalf of Class II test products | |
4 | Mode: 1p, 2p, 1+NPE, 3p, 4p, 3+NPE |
Model | LH-80 | LH-100 | LH-120 | LH-150 | LH-200 |
Maximum continuous operating voltage Uc | 275/320/385/440V~ (optional can be customized) | ||||
Nominal discharge current In (8/20) | 40 | 60 | 60 | 80 | 100 |
Maximum discharge current Imax (8/20) | 80 | 100 | 120 | 150 | 200 |
Protection level Up | ≤1.8/2.0/2.3/2.4KV | ≤2.0/2.2/2.4/2.5KV | ≤2.3/2.5/2.6/2.7KV | ≤2.5/2.7/2.9/3.0KV | ≤2.7/3.0/3.2/3.5KV |
Optional appearance | Plane, full arc, arc (optional, customizable) | ||||
Can add remote signal and discharge tube | Can add remote signal and discharge tube | ||||
working environment | -40 ℃~+85℃ | ||||
Relative humidity | ≤95%(25℃) | ||||
colour | White, red, orange (optional, can be customized) | ||||
Remark | Power surge protector, suitable for three-phase five-wire power supply system, guide rail installation. |