Usually customer-oriented, and it’s our ultimate focus on to be not only by far the most reliable, trustable and honest provider, but also the partner for our customers for Factory source China Export Qt4-36 Small Scale Semi Automatic Sand Stone Fly Ash Slag Hollow Paving Interlocking Solid Curbstone AAC Cement Concrete Block Brick Making Machine Price, We respect your enquiry and it truly is our honor to operate with each friend around the world.
Usually customer-oriented, and it’s our ultimate focus on to be not only by far the most reliable, trustable and honest provider, but also the partner for our customers for China Concrete Brick Making Machine Line, Construction Equipment, Our company offers the full range from pre-sales to after-sales service, from product development to audit the use of maintenance, based on strong technical strength, superior product performance, reasonable prices and perfect service, we’ll continue to develop, to offer the high-quality solutions and services, and promote lasting cooperation with our customers, common development and create a better future.
When the thunderstorm season is coming, lightning protection is particularly important at this time. Lightning enters the room through power lines or other ways, causing damage to people and equipment; LEIHAO Lightning Protection Company has many excellent lightning protection products, of which the surge protector of power supply is an important part. Now we will briefly introduce the parameters and uses of a first-class surge protector.
(1) in the front end of the main power switch in the floor distribution box, LH-50I 4P is generally used as the primary protection of power supply;
② LH-50I 4P should also be used at the low voltage end of transformer and the front end of main power switch.
③ When the distribution box is independent outdoors, LH-50I 4P should also be used as the primary power protection.Equipment connected to AC power supply network is easily affected by many electrical problems that may be expected in unstable operation, which leads to equipment failure, life reduction and even damage. LH-15I series surge protectors are designed to meet the protection requirements of all low-voltage devices for industrial lightning surge. The product range of this series is classified by product type and power supply category (AC or DC).
LH-12.5I/3p
Maximum continuous operating voltage Uc 385V~
Nominal discharge current In 12.5KA
Impulse discharge current Iimp 12.5KA
Voltage protection level Up ≤2.5KV
Full arc, no window, pad printing, graphite
LH-15I/4p
Maximum continuous operating voltage Uc 385V~
Nominal discharge current In 15KA
Impulse discharge current Iimp 15KA
Voltage protection level Up ≤2.0KV
Full arc, window, pad printing, chip
LH-25I/4p
Maximum continuous operating voltage Uc 385V~
Nominal discharge current In 25KA
Impulse discharge current Iimp 25KA
Voltage protection level Up ≤2.2KV
Full arc, no window, pad printing, graphite
MODEL: |
LH |
Lightning pick surge protector |
12.5 |
Impulse discharge current: 12.5, 15, 20, 25, 30KA…… | |
I |
I: stands for T1 products; default: stands for T2 products | |
385 |
Maximum continuous operating voltage: 385, 440V~ | |
4 |
Mode: 1p, 2p, 1+NPE, 3p, 4p, 3+NPE |
Model | LH-12.5I | LH-15I | LH-20I | LH-25I | LH-30I | LH-50I |
Maximum continuous operating voltage Uc | 275/320/385/440V~(Optional and customizable) | |||||
Nominal discharge current In (8/20) | 12.5KA | 15KA | 20KA | 25KA | 30KA | 50KA |
Impulse discharge current Iimp (10/350) | 12.5KA | 15KA | 20KA | 25KA | 30KA | 50KA |
Protection level | ≤1.5/1.8/2.5/2.5KV | ≤1.5/1.8/2.5/2.5KV | ≤1.8/2.0/2.2/2.5KV | ≤1.8/2.0/2.2/2.5KV | ≤2.0/2.2/2.5/3.0KV | ≤2.0/2.2/2.5/3.0KV |
Optional appearance | Full arc, half arc, window, no window, word, no word (optional, can be customized) | |||||
Built-in chip, graphite, remote signal, | Graphite, chip Can add remote letter | Graphite, chip Can add remote | graphite | graphite | graphite | graphite |
Working environment | -40 ℃~+85℃ | |||||
Relative humidity | ≤95%(25℃) | |||||
Colour | White, red (optional, customizable) | |||||
Remark | Power surge protector, suitable for three-phase five-wire power supply system, guide rail installation. |
1. product design standard: this product is designed according to relevant international standards IEC, and its performance meets the requirements of national standard GB 18802.1-2011 “low voltage surge protector (SPD) part 1: performance requirements and test methods of surge protector for low voltage distribution system”.
2. Scope of product use: GB50343-2012 Technical Code for Lightning Protection of Building Electronic Information System
3 Selection of surge protector: The primary SPD must be set in the main distribution box at the entrance of building power supply.
4. Product features: This product has the characteristics of low residual voltage, fast response speed, large current capacity (impulse current Iimp(10/350μs) is 25kA/ line, long service life, simple maintenance and convenient installation, etc.
5.Working temperature: -25℃ ~+70℃, working humidity: 95%.
Risk of voltage surges
Electrical and electronic eauipment is indispensable in the daily activities of today’s businesses and individuals. Such devices are connected to the electricity grid, often exchanging data and signals through communication lines and are usually sensitive to disturbances. These interconnecting networks provide a propagation path for overvoltages.
Protection against lightning and overvoltages not only ensures the safety of people,goods and equipment, but also ensures continuity of installation services. Overvoltage protection extends the life of the equipment by more than 20%, which significantly reduces the volume of electronic waste. It also reduces the power consumption of the installations, all of which translates into cost savings and environmental sustainability.
OUR SERVICE:
1.quick response in before sales period help you got order.
2.excellent service in production time let you know each step we made.
3.reliable quality solve you after sale headache.
4.long period quality warranty ensure you can buy without hesitate.
Quality assurance:
1. Strict control on choose of the raw material sources.
2. Speciific technology guide for the production of each product.
3. Completed quality testing system for the semi-finished products and finised products.
To better ensure the safety of your goods, professional, environmentally friendly, convenient and efficient packaging services will be provided.
Usually customer-oriented, and it’s our ultimate focus on to be not only by far the most reliable, trustable and honest provider, but also the partner for our customers for Factory source China Export Qt4-36 Small Scale Semi Automatic Sand Stone Fly Ash Slag Hollow Paving Interlocking Solid Curbstone AAC Cement Concrete Block Brick Making Machine Price, We respect your enquiry and it truly is our honor to operate with each friend around the world.
Factory source China Concrete Brick Making Machine Line, Construction Equipment, Our company offers the full range from pre-sales to after-sales service, from product development to audit the use of maintenance, based on strong technical strength, superior product performance, reasonable prices and perfect service, we’ll continue to develop, to offer the high-quality solutions and services, and promote lasting cooperation with our customers, common development and create a better future.
|
Shell material: PA66/PBT Feature: One-piece module Remote control monitoring function: with configuration Shell color: default, customizable Flame retardant rating: UL94 V0 |
|
●The power must be cut off before installation, and live operation is strictly prohibited ●It is recommended to connect a fuse or automatic circuit breaker in series at the front of the lightning protection module ●When installing, please connect according to the installation diagram. Among them, L1, L2, L3 are phase wires, N is the neutral wire, and PE is the ground wire. Do not connect it wrongly. After installation, close the automatic circuit breaker (fuse) switch ●After installation, check whether the lightning protection module is working properly 10350gs, discharge tube type, with window: during use, the fault display window should be checked and checked regularly. When the fault display window is red (or the remote signal terminal of the product with remote signal output alarm signal), it means the lightning protection module In the event of failure, it should be repaired or replaced in time. ●Parallel power supply lightning protection modules should be installed in parallel (Kevin wiring can also be used), or double wiring can be used. Generally, you only need to connect any one of the two wiring posts. The connecting wire must be firm, reliable, short, thick, and straight. Installation diagram