• page_head_bg

Product Model

Surge protector selection

The power surge protector is divided into three levels: level one (level B), level two (level C), and level three (level D). According to the IEC (International Electrotechnical Commission) standard of the divisional lightning protection and multi-level protection theory, Class B lightning protection belongs to the first-level lightning protection device, which can be applied to the main power distribution cabinet in the building; Class C belongs to the second-level protection Lightning devices are used in the branch distribution cabinets of buildings; Class D is a third-level lightning protection device, which is used in the front end of important equipment to provide fine protection to the equipment.

Power lightning protection module series

36 Cidale Surge Selection (10/350μ s)

LH-12.5I
Maximum continuous operating voltage Uc 385V~
Nominal discharge current In 12.5KA
Maximum discharge current Imax 12.5KA
Voltage protection level Up ≤2.0KV
LH-15I
Maximum continuous operating voltage Uc  385V~
Nominal discharge current In 15KA
Maximum discharge current Imax  15KA
Voltage protection level Up  ≤2.0KV
LH-25I
Maximum continuous operating voltage Uc 385V~
Nominal discharge current In 25KA
Maximum discharge current Imax 25KA
Voltage protection level Up ≤2.2KV

18OB surge selection (8/20μ s)

LH-20/4p
Maximum continuous operating voltage Uc  385V~
Nominal discharge current In  10KA
Maximum discharge current Imax  20KA
Voltage protection level Up ≤ 1.6KV
LH-40/4p
Maximum continuous operating voltage Uc  385V~
Nominal discharge current In 20KA
Maximum discharge current Imax  40KA
Voltage protection level Up  ≤ 1.8KV
LH-80/4p
Maximum continuous operating voltage Uc 385V~
Nominal discharge current In  40KA
Maximum discharge current Imax  80KA
Voltage protection level Up  ≤ 2.3KV

18 shield surge selection (8/20μ s)

LH-20/3p
Maximum continuous operating voltage Uc 690V
Nominal discharge current In  10KA
Maximum discharge current Imax 20KA
Voltage protection level Up ≤2.0KV
LH-40/4p
Maximum continuous operating voltage Uc 385V
Nominal discharge current In 20KA
Maximum discharge current Imax  40KA
Voltage protection level Up ≤ 1.8KV
                LH-40/3+NPE                                             NPE
Maximum continuous operating voltage Uc 385V    255V~
Nominal discharge current In 20KA     20KA
Maximum discharge current Imax 40KA     40KA
Voltage protection level Up ≤1.8KV  ≤1.3KV

 

 

27OBO surge selection (8/20μ s)

LH-80/4p
Maximum continuous operating voltage Uc  385V~
Nominal discharge current In 40KA
Maximum discharge current Imax  80KA
Voltage protection level Up ≤ 2.3KV
LH-80/4p
Maximum continuous operating voltage Uc 385V~
Nominal discharge current In 40KA
Maximum discharge current Imax  80KA
Voltage protection level Up ≤ 2.3KV
LH-100/4p
Maximum continuous operating voltage Uc 385V~
Nominal discharge current In 60KA
Maximum discharge current Imax 100KA
Voltage protection level Up ≤ 2.5KV

36 Cidell surge selection (8/20μ s)

LH-200/4p
Maximum continuous operating voltage Uc 385V~
Nominal discharge current In 100KA
Maximum discharge current Imax 200KA
Voltage protection level Up ≤ 3.6KV
LH-100/4p
Maximum continuous operating voltage Uc  385V~
Nominal discharge current In 60KA
Maximum discharge current Imax 100KA
Voltage protection level Up  ≤ 2.5KV
LH-160/4p
Maximum continuous operating voltage Uc  385V~
Nominal discharge current In  80KA
Maximum discharge current Imax  160KA
Voltage protection level Up ≤ 3.2KV

Lightning protection power strip selection

LH-803
Maximum continuous operating voltage Uc  275V~
Nominal discharge current In  5KA
Maximum discharge current Imax  10KA
Voltage protection level Up  1.2KV
LH-807
Maximum continuous operating voltage Uc  275V~
Nominal discharge current In  5KA
Maximum discharge current Imax  10KA
Voltage protection level Up  1.2KV
LH-PDU/6
Maximum continuous operating voltage Uc  275V~
Nominal discharge current In  5KA
Maximum discharge current Imax  10KA
Voltage protection level Up  1.2KV

Intelligent surge selection

Intelligent Surge
LH-ZN/40
Maximum continuous operating voltage Uc  385V~
Nominal discharge current In  20KA
Maximum discharge current Imax  40KA
Voltage protection level Up  ≤ 1.8KV
Intelligent Surge
LH-ZN/60
Maximum continuous operating voltage Uc  385V~
Nominal discharge current In  30KA
Maximum discharge current Imax  60KA
Voltage protection level Up  ≤ 2.0KV
Intelligent Surge
LH-ZN/80
Maximum continuous operating voltage Uc  385V~
Nominal discharge current In  40KA
Maximum discharge current Imax  80KA
Voltage protection level Up  ≤ 2.3KV

Signal lightning protection device series

Signal lightning protection device selection

LH-X-24
18 signal 485 lightning protection device
Maximum continuous operating voltage Uc  30V
Nominal discharge current In  3KA
Maximum discharge current Imax  5KA
LH-AF/220
Network camera lightning protection device (two in one)
Maximum continuous operating voltage Uc  320V~
Nominal discharge current In  5KA
Maximum discharge current Imax 10KA
LH-AF3/220
Three-in-one lightning protection device
Maximum continuous operating voltage Un 220V~
Nominal discharge current In 10KA
Maximum discharge current Imax 20KA

LH-AF/24

Network camera lightning protection device (two in one)
Power supply: Maximum continuous operating voltage Uc  30V~
Nominal discharge current In  3KA
Maximum discharge current Imax  5KA
Network:     Un: 5V   Uc: 6.5V~
LH-RJ45
Network single-port lightning protection device
Maximum continuous operating voltage Uc  8V
Nominal discharge current In 3KA
Voltage protection level Up  ≤ 45V

Power lightning protection box series

Three-phase lightning protection box selection

LH-40-SX
Maximum continuous operating voltage Uc 385V~
Nominal discharge current In 20KA
Maximum discharge current Imax 40KA
Voltage protection level Up ≤ 1.8KV

Single-phase lightning protection box selection

LH-80-DX
Maximum continuous operating voltage Uc 385V~
Nominal discharge current In 40KA
Maximum discharge current Imax 80KA
Voltage protection level Up ≤ 2.3KV

Switch protector series

LH-SCB-40
Maximum continuous operating voltage Uc 230V-320V~
Maximum discharge current Imax 40KA