Single-phase power lightning protection box

Single-phase power lightning protection box

Short Description:

This product is widely used in mobile communication base stations, microwave communication bureau stations, telecommunications equipment rooms, industrial factories and mines, civil aviation, finance, securities and other power systems, such as various power distribution stations, power distribution rooms, power distribution cabinets, AC and DC power distribution panels, Switch boxes and various other important equipment that is vulnerable to lightning strikes.


Product Detail

Installation Notes

Product Tags

● The snow box with the maximum discharge current of 120kA and above is suitable for the lightning protection of the total power supply in important places;
● The lightning protection box with the maximum discharge current of 40-80kA is suitable for lightning protection of various power systems (such as UPS power supply, computer room power supply, etc.);
● The lightning protection box with a maximum discharge current of 120kA is suitable for lightning protection of various equipment power supplies.

Features

●Lightning counter (lightning protection box with lightning counter), accurately record the number of lightning strikes
●Status indicator, indicating the working status of the lightning protection box.
●The discharge current is large and the residual voltage is low.
●Wide range of use, ns-level response speed.
●Realize all-round protection of differential mode and common mode.
●Using special impact fuse, high reliability.
●The core components adopt internationally renowned brands with superior performance and long service life.
●There are temperature control and current limiting circuits inside to completely avoid fire.
●Energy saving, environmental protection, simple and convenient installation, no special maintenance.

Product Size

FeaturesModel meaning

Lightning Protection Box Product Size

LH-100I/X385-S

LH Lightning pick surge protector
100 Maximum discharge current: 40, 80, 100kA...
I I; Represents T1 products; Default: Represents T2 products
X AC system box type
385 Maximum continuous operating voltage: 385, 440V~
S D: Single phase; S: Three phase

Technical parameter

Model

LH-20-DX

LH-40-DX

LH-60-DX

LH-80-DX

LH-100-DX

LH-120-DX

Maximum continuous working voltage Uc

385V~

Nominal discharge current (8/20μS) In

10KA

20KA

30KA

40KA

60KA

60KA

Maximum discharge current Imax (8/20μ S)

20KA

40KA

60KA

80KA

100KA

120KA

Protection level Up

≤1.5kv

≤1.8kv

≤2kv

≤2kv

≤2.5kv

≤2.5kv

Response time tA

≤25ns

Built-in circuit breaker

32A

Power indicator and lightning protection indicator

Red light on means normal, red light off means failure

Wiring

In parallel

memory function

No data loss when power off

Power display range of lightning technology counter

0~9999

Operation of Lightning Technician

Clear, preset

Working temperature zone

-40 ℃~+80℃

Wiring specifications

6mm² ~25mm²

Shell material

Metal

Shell protection level

IP20

size

230mm*300mm*95mm

Counter response (rising ≥ 8μ S)

≥0.2KA

Counting interval

≥2s

Lightning Technician Power Supply

220V~

humidity

≤90% (average 25℃)

environment

Non-flammable and explosive environment

Not affected by sunlight, rain, etc.

Structure and Principle

Lightning protection box in parallel to the protected equipment front-end, under the condition of normal operating voltage, power supply lightning protection box in a high impedance state, does not affect the normal work of the circuit. When there is pulse surge line lightning strike, power lightning protection box in the nanosecond time conduction, quickly put the overvoltage of diarrhea in the earth, when the pulse over-voltage  disappears, power lightning protection box and automatic recovery to a high resistance state, does not affect the line power supply. With module alarm indicator, provide module deterioration indication 4With power status indicator lamp to indicate the working status of lightning arrester , Equipped with lightning counter to accurately record the number of lightning strikes

FQA:
Q: Can I get some samples?
A: Yes, Sample orders welcomed.

Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are available.

Q:What is the delivery time?
A: 3 days for samples, 7-10 working days for mass production after payment.

Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc

Q: Can I trust you?
A: Absolutely YES, We are "Made In China" verified supplier for many years.

Q: May I visit your factory?
A:Sure, welcome any time. We can also pick you up at airport or station.

OUR SERVICE:

1.quick response in before sales period help you got order.
2.excellent service in production time let you know each step we made.
3.reliable quality solve you after sale headache.
4.long period quality warranty ensure you can buy without hesitate.

Quality assurance:

1. Strict control on choose of the raw material sources.
2. Speciific technology guide for the production of each product.
3. Completed quality testing system for the semi-finished products and finised products.

To better ensure the safety of your goods, professional, environmentally friendly, convenient and efficient packaging services will be provided.


  • Previous:
  • Next:

  • ●The power must be cut off before installation, and live operation is strictly prohibited
    ●The lightning protection box can be hung on the wall or placed horizontally.
    ●When installing, please connect according to the installation diagram. Among them, L, L2, L3 are phase wires, N is the neutral wire, and PE is the ground wire. Do not connect it wrongly. After the installation is complete, close the automatic circuit breaker (fuse) switch and check whether the working state is normal
    ●During the use of the lightning protection box, you should regularly check and check the working status of the indicator: the indicator light is green, indicating that the power supply and lightning protection of the lightning protection box are normal; bright red indicates that the lightning protection box has deteriorated and should be repaired or replaced in time.
    ●The lightning protection box equipped with lightning counter has a counting range of 0-9, and the minimum operating current is 1kA. Press the “reading” button, and the window will display the number of lightning strikes. If you do not operate for 20 seconds, the counter will automatically enter the sleep state.
    ●The connecting wire should be a multi-strand copper wire not less than the standard requirement, and it should be short, thick and straight.

    Single-phase power lightning protection box 001